background image

application guide safety relays from riese electronic

page 138

Product Application for

- emergency stop relay

- safety gate monitoring relay

-

safety mats





Dual-channel emergency stop

(with opposite between channels)


By pressing the start button, the safety contacts
13-14 and the segment will close. Pressing the
emergency stop switch will reset the safety
contacts and interrupt the segment circuit.

Suitable up to

category 4, PLe, SIL 3 reachable




Dual-channel protection door monitoring

with opposite polarity between channels.


If the safety gate switches are closed, the output
contacts remain unchanged. After the release of
the unit, the contact 13-14 closes. After opening
the protection door switches the contacts return
to their normal position without delay.

Suitable up to

category 4, PLe, SIL 3 reachable


Dual-channel application for four-wire-safety-

mats (with opposite polarity between

channels)


Example 7 and 8 are possible only with mats,
which operate according to the contact principle.
I.e. the mat must switch when loading
immediately to 0 Ohms.
The activation works automatically, since the
terminals S33 -S34 and S51-S52 are bridged.
Contact 13-14 closes after power is on or after
steps off the safety mat. The turn on time
amounts to after 10s loading of the mat approx.
1s.

Suitable up to category 1,PLc, SIL1 reachable

START

S52

S33 S34 S51

S41

S42

S11

S22

S21

S12

NOT-

STOP

E-

AUS/

S33 S34

S52

S51

S41

Freigabe/

release

S12

S42

S11

S21 S22

S2

S1

S33

S41 S42

S52

S34

S51

S11

S21

S12

S22

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866

Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com

Advertising