Combination Firing
In the Combination firing, the crystallization of IPS e.max CAD and Glaze firing are performed in one step.
Characterizations and the glaze may be applied in two ways.
Please note the different procedures when using the IPS e.max CAD Crystall./Glaze Spray and the IPS e.max CAD
Crystall./Glaze Paste.
Staining
Technique
Option A:
Crystallization and Stain/Glaze firing in one step with
IPS e.max CAD Crystall./Glaze Spray
Option B:
Crystallization and Glaze firing in one step with
IPS e.max CAD Crystall./Glaze paste
– Characterization on the uncrystallized, blue restora-
tion
– Application of the Glaze Spray
– Firing program Speed Crystallization/Glaze Spray at
most 2 restorations with Glaze Spray,
duration 20 minutes
– Application of the glaze paste and the characteriza-
tions on the uncrystallized, blue restoration
– Firing program Crystallization/Glaze,
duration 25 minutes