Can machined IPS e.max CAD restorations in

the pre-crystallized (blue) state be completely

finished and then just crystallized and

glazed?

Milled IPS e.max CAD restorations should be care-

fully tried in and finished in their pre-crystallized

(“blue”) state. In the blue state, special attention

must be paid to the restoration margins. The

margins should be created in relation to the

preparation and the thickness of the restoration.

Do IPS e.max CAD restorations shrink during

crystallization?

No. During the crystallization process, the micro-

structure becomes transformed and a densifica-

tion of 0.2 % takes place. The CAD software

takes the densification factor into account.

Therefore, the milled IPS e.max CAD restorations

demonstrate precision of fit after crystallization.

No further manual adjustments are necessary.

Why does the auxiliary firing paste IPS Object

Fix Putty or Flow have to be used during the

crystallization process?

The auxiliary firing paste ideally supports

IPS e.max CAD restorations during crystallization,

which ensures that the restorations demonstrate

optimum accuracy of fit.

Can firing pastes other than

IPS Object Fix Putty or Flow be used in the

crystallization process?

IPS Object Fix Putty and Flow has been speically

developed for the crystallization of IPS e.max CAD

restorations. The expansion behaviour has been

optimally coordinated with IPS e.max CAD. In

other words, the consistency before and after the

crystallization allows the paste to be easily applied

and cleanly removed. Given their composition,

pastes of other manufacturers may cause damage

to IPS e.max CAD. Furthermore, easy removal may

not always be possible.

46

How can the restoration be filled with

IPS Object Fix Putty?

IPS Object Fix Putty can be filled into the inner

aspect of the restoration with the help of a plastic

spatula (e.g. OptraSculpt). Alternatively, a small

amount of IPS Object Fix Putty may be rolled

between the fingers and then pressed into the

restoration. IPS Object Fix Putty excess which is

forced out when the IPS e.max CAD Crystallization

Pin is pressed into the putty can also be adapted

with a plastic spatula or the fingers. Always make

sure, however, that the outer surface of the

restoration is not contaminated with IPS Object

Fix.

How are contaminations with IPS Object Fix

Putty or Flow on the outer surface of the

restorations best removed before

crystallization?

A brush, a cotton swab or a microbrush

dampened with water can be used for cleaning.

It must be made sure that any residue has been

removed before Shades, Stains or Glaze are

applied in order to prevent the residue from being

burned in.

How can a premature drying of the

IPS Object Fix Putty or Flow in the syringe be

prevented?

In order to avoid a premature loss of moisture of

the firing pastes, remove the syringe from the

aluminium bag only directly before initial use.

Close the syringe immediately after usage. If the

syringe is not used for a longer period of time, it

can be stored in a resealable plastic bag together

with a moist paper tissue.