47

Can other firing trays, e.g. honey-combed

trays, be used for the crystallization of

IPS e.max CAD?

No other firing trays should be

used. The IPS e.max CAD

Crystallization Tray contained in

the assortment stores the heat

necessary for slow and above all

tension-free cooling of the glass-

ceramic. Other firing trays, e.g.

honey-combed tray, cannot store the heat and

therefore cool down too quickly.

Can furnaces other than the ones from

Ivoclar Vivadent be used to crystallize

IPS e.max CAD restorations?

The crystallization of IPS e.max CAD is specially

coordinated with the Ivoclar Vivadent ceramic

furnaces (e.g. Programat CS). If you would like to

use other ceramic furnaces, please consult Ivoclar

Vivadent about their compatibility with IPS e.max

CAD. It is important to note that not every

ceramic furnace can be used for crystallization.

Ceramic furnaces which, for example, do not

feature a controlled (long-term) cooling mode or

vacuum cannot be used for this purpose.

Can IPS e.max CAD Crystall./Add-On also be

fired with the parameters Speed

Crystallization/Glaze Spray?

No. Since the IPS e.max CAD Crystall./Add-On

Liquid contains organic components that only

slowly evaporate during pre-drying, the parame-

ters Speed Crystallization/Glaze Spray cannot be

used due to the short closing time.

Can the IPS e.max CAD Crystall./Glaze Paste

also be fired with the parameters Speed

Crystallization/Glaze Spray?

No. Since the IPS e.max CAD Crystall./Glaze Paste

contains organic components that only slowly

evaporate during pre-drying, the parameters

Speed Crystallization/Glaze Spray cannot be used

due to the short closing time.

Can IPS Empress Universal Shades, Stains and

Glaze be used for IPS e.max CAD?

IPS Empress Universal Shades, Stains and Glaze

were specially developed for and coordinated with

the IPS Empress System and are therefore not

suitable for IPS e.max products.

What must be considered after the firing of

IPS e.max CAD?

In order to prevent tensions within the ceramic,

remove the restoration from the furnace only

after the firing cycles have been completed (wait

for the acoustic signal of the ceramic furnace.

Allow the objects to cool to room temperature in

a place protected from draft and do not touch

them with metal tongs during that time. Do not

blast or quench the objects.

Can IPS e.max CAD restorations be blasted

with Al

2

O

3

or glass polishing beads (on the

cavity side) as a preparation for the seating?

IPS e.max CAD restorations must not be blasted

with Al

2

O

3

or glass polishing beads before

placement, as this damages the ceramic surface

and significantly reduces the strength.

How must the internal (bonding) surface

of the IPS e.max CAD restorations be

conditioned before cementation?

The internal (bonding) surfaces of IPS e.max CAD

restorations must always be etched with 5%

hydrofluoric acid etching gel (IPS Ceramic Etching

Gel) for 20 seconds, irrespective of whether they

are cemented with adhesive, self-adhesive or

conventional methods. The resulting retentive

pattern enables an enhanced bond both with

adhesives and self-adhesives, as well as con-

ventional bonding agents. After etching, the

glass-ceramics are silanized using Monobond-S

when adhesive and self-adhesive cementation is

used. With conventional cementation, silanizing is

not necessary.