33

Staining

Technique

Problem/Cause

Before Firing

Application of the Glaze Spray

After Firing

Detailed view of the surface

Insufficient application of IPS e.max CAD Crystall./Glaze Spray

Problem:

Not enough Glaze Spray on the restora-

tion

Possible cause:

– Distance between the spray can and the

restoration too far

– Spraying too short

– Spray can not shaken sufficiently

– Spray can held not upright during

spraying

Insufficient gloss or imcomplete glossy layer

Too much IPS e.max CAD Crystall./Glaze Spray applied

Problem:

Too much Glaze Spray on the restoration

Possible cause:

– Distance between the spray can and the

restoration too close

– Too much Glaze Spray applied

Loss of texture and too glossy surface

Example of incorrect Glaze Spray application