6 daten-logging-datei (logdatei) – beispiel, Typ 8620 mxcontrol – Burkert Type 8620 Benutzerhandbuch
Seite 178

„Typ 8620 mxCONTROL“
Seite 178
21.6
Daten-Logging-Datei (Logdatei) – Beispiel
#HEADER
DatalogFile
Rev
A.00
Source
DEVICE
Device
ID
188133
Serial
1001
Firmware
ID
797645
Rev
C.00.00.00
Project
Name
Project
ABCD
Cfg-File
Name
Project_ABCD.cfg
Applied
19.04.2010 14:33:19
Param-File
Name
Project_ABCD.par
Applied
21.04.2010 12:19:52
#PROCESSDATA
Zeile 1:
CL ORP
Cond Control
Biocide Dosing
Zeile 2:
CL
ORP
Cd
BioDos
Zeile 3:
0-0-1 0-0-2
0-1-1 0-1-2
0-2-1 0-3-1 1-11-1 1-11-2
1-11-7
1-11-20
1-11-21
2-8-1 2-8-2
2-8-7 2-8-20 2-8-21 3-10-24 3-10-20 3-10-21 3-10-25 3-10-22 3-10-23
Zeile 4:
date time
hex str
fl fl fl str
fl fl str fl str
fl fl str
fl fl str fl fl str
Zeile 5:
Date Time
LogEvent
Event
Manual
Mode
Common
Alarm PV1
State
PV1 SP CMD
State
CMD PV1
State
PV1 SP
CMD
State
CMD
State
Ch1 CMD1
State
CMD1
State
Ch2 CMD2
State
CMD2
Zeile 6:
CL ORP
CL ORP
Cond
Bleed
Bioci-
de 1
Bioci-
de 2
Zeile 7:
YYYY-MM-DD HH:MM:SS
mV
mV
%
µS/cm
µS/cm
%
%
%
2010-04-22
13:32:13 00000014
LogEvent
0 0 458.52
OK
500.00
0.00
fS 823.45 OK
1000.0
0.00 fS 7
0.00 fS
7
0.00 fS
2010-04-22
13:32:33 00000080
Mask:
0 0 441.87
OK
500.00
0.00
fS 901.61 OK
1000.0
0.00 fS 7
0.00 fS
7
0.00 fS
2010-04-22
13:32:40 00010000
ffffffff
0 0 441.45
OK
500.00
100.00
Au 902.08 OK
1000.0
0.00 Au 1
0.00 Au
1
0.00 Au
2010-04-22
13:32:53 00000080
0
0
442.35 OK 500.00 100.00 Au
901.59 OK 1000.0
0.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:32:59 00010000
0
0
441.99 OK 500.00 100.00 Au
1040.3 OK 1000.0
100.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:33:13 00010080
0
0
513.63 OK 500.00 0.00
Au
1040.3 OK 1000.0
100.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:33:17 00010000
0
0
513.63 OK 500.00 0.00
Au
779.60 OK 1000.0
0.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:33:20 00100000
1
0
513.63 OK 500.00 20.00
Ma
933.40 OK 1000.0
0.00 Ma 0
0.00 Ma 0
0.00 Ma
2010-04-22
13:33:33 00010080
1
0
513.74 OK 500.00 20.00
Ma
932.91 OK 1000.0
100.00 Ma 0
0.00 Ma 0
0.00 Ma
2010-04-22
13:33:53 00000080
1
0
520.74 OK 500.00 20.00
Ma
931.30 OK 1000.0
100.00 Ma 0
0.00 Ma 0
0.00 Ma
2010-04-22
13:35:00 00110000
0
0
524.10 OK 500.00 0.00
Au
933.41 OK 1000.0
0.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:35:05 0a010000
0
1
530.19 AH 500.00 0.00
Au
1069.2 OK 1000.0
100.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:35:13 00000080
0
1
532.10 AH 500.00 0.00
Au
1071.6 OK 1000.0
100.00 Au 1
0.00 Au 1
0.00 Au
2010-04-22
13:35:23 0a010000
0
1
535.38 AH 500.00 0.00
Au
--
FI
1000.0
0.00 YS 1
0.00 Au 1
0.00 Au
und so weiter …
Es werden ausgangsseitig nur die Modulausgänge CMD geloggt.
Ausnahme für Transistorausgänge im PWM- oder Fast-PWM-Modus: