3 device profile specific objects – Baumer BA_DSRT_22DJ Benutzerhandbuch

Seite 34

Advertising
background image

Manual_CANopen_StrainLink_EN_V3_05.doc

34/65

Baumer

22.07.11/dam

Frauenfeld, Switzerland

6.3 Device profile specific objects

Setting and interrogating the sensor-specific values. The following indices are supported:

Object Name

6110

Sensor type

6112

Operating mode

6125

Autozero

6131

Physical unit PV

6132

Decimal unit PV

6150

Status of measurement

7130

Process value 16bit

7133

Interrupt delta input 16bit

8130

Process value 24bit

8133

Interrupt delta input 24bit

6.3.1

Sensor type

Read sensor type (object 6110h):

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

600h + ID

8

40h

10h

61h

01h

0

0

0

0


Response from CANopen strain link:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

580h + ID

8

4Bh

10h

61h

01h

46h

00h

0

0


Byte 5:

46h

strain link


The object 6110h is read only.

6.3.2

Operation mode

When delivered, the sensor is always in normal mode.

Read operation mode (object 6112h):

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

600h + ID

8

40h

12h

61h

01h

0

0

0

0


Response from CANopen strain link:

ID

DLC

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

Byte8

580h + ID

8

4Fh

12h

61h

01h

01h

0

0

0


Byte 5:

01h

Acquisition mode

02h – 09h

reserved

0Ah

(Adjust mode)


The object 6112h is read only.