Baumer BA_DSRT_22DJ Benutzerhandbuch
Seite 56

Manual_CANopen_StrainLink_EN_V3_05.doc
56/65
Baumer
22.07.11/dam
Frauenfeld, Switzerland
7.5.3
Configuration mode direct connection (master sensor)
To use LSS the sensor has to be in the LSS configuration mode.
The sensor can be set into the LSS configuration mode as follows:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
7E5
8
04h
01h
0
0
0
0
0
0
The current set ID can be interrogated to test if the sensor has switched into the configuration mode:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
7E5
8
5Eh
0
0
0
0
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
7E4
8
5Eh
01h
0
0
0
0
0
0
Example “ID 1“
Byte 2:
01h
accessed sensor has ID 1
If the sensor does not respond, the sensor does not support LSS or the baud rate is incorrect. For safe
access the service and its baud rates has to be tested.
Now the ID or the baud rate can be changed.
7.5.4
Configuration mode of a sensor in a network
With the following orders the sensor can be identified:
Transmission of vendor ID:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
7E5
8
40h
5Fh
00h
00h
00h
0
0
0
Vender ID:
Byte 1:
40h
System byte vender ID
Byte 2 – 5:
5F’00’00’00h
00’00’00’5F (LSB first)
Firma Baumer electric
Transmission of product code:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
7E5
8
41h
44h
0Dh
A8h
00h
0
0
0
Product code:
Byte 1:
41h
System byte product code
Byte 2 – 5:
44’0D’A8’00h
00’A8’0D’44 (LSB first)
11013444 in decimal
Transmission of revision number:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
7E5
8
42h
01h
02h
03h
00h
0
0
0
Revision number:
Byte 1:
42h
System byte revision number
Byte 2 – 5:
01’02’03’00h
00’03’02’01 (LSB first)
00030201h