Manual_CANopen_StrainLink_EN_V3_05.doc

62/65

Baumer

22.07.11/dam

Frauenfeld, Switzerland

4. Disable PDO1 output

5. Modify PDO1 mapping

No.:

01h => 1

st

mapped object in PDO1

Leng.:

10h => 16 bit data length of mapped object

Sub.:

01h => mapped sub-index = 01h

map. Index: 30’71h => mapped index = 71’30h

No.:

01h => 1

st

mapped object in PDO1

Leng.:

18h => 24 bit data length of mapped object

Sub.:

01h => mapped sub-index = 01h

map. Index:

30’81h => mapped index = 81’30h

6. Enable PDO1 mapping

01h => 1 mapped object with PDO1

01h => 1 mapped object with PDO1

7. Enable PDO1 mapping

Measurement cycle:

Sensor to operational mode

Master

Slave

01h

ID

DLC

2

ID

0

Byte1 Byte2

Master

Slave

01h

ID

DLC

2

ID

0

Byte1 Byte2

a

fte

r 1

s

a

fte

r 1

s

a

fte

r 1

s

a

fte

r 1

s

16-Bit

16-Bit

24-Bit

24-Bit