7 emergency and services, 1 error register and history – Baumer BA_DSRT_22DJ Benutzerhandbuch
Seite 49

Manual_CANopen_StrainLink_EN_V3_05.doc
49/65
Baumer
22.07.11/dam
Frauenfeld, Switzerland
7 Emergency and services
7.1 Error register and history
7.1.1
Error register
Read error register (object 1001h):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
40h
01h
10h
00h
0
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
4Fh
01h
10h
00h
81h
0
0
0
Byte 5:
81h
a manufacture error has occurred
Bit 0=1
error occurred
Bit 7=1
manufacturer specific error
The object 1001h is read only and has no sub-index.
7.1.2
Emergency History
The object 1003h stores the last 16 error messages (Emergency Messages) which have occurred during
operation in the RAM. This means that at the next loss of power or manual deletion the data is deleted. The
recording will be deleted if 00h is written on the sub index 0.
The object has the following structure:
Index
Sub-index
Name
Length
Access
0
Number of errors
1 byte
Read/Write
1003h
1...16
Error messages
8 byte
Read
Read number of errors (sub-Index 0):
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
40h
03h
10h
00h
0
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
4Fh
03h
10h
00h
02h
0
0
0
Byte 5:
02h
2 error messages have been recorded
Delete the emergency messages by writing 0 to sub-index 0:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
600h + ID
8
22h
03h
10h
00h
00h
0
0
0
Response from CANopen strain link:
ID
DLC
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
Byte8
580h + ID
8
60h
03h
10h
00h
0
0
0
0