8.3 Set and request of process value with PDO1 (16 and 24bit)

Initialize of measurement:

1. Set data type (object 21’12h)

24-Bit

71’30h => 16 bit process value

81’30h => 24 bit process value

2. Request unit (object 61’31h)

FA’01’01’00h => µ

ε

or µm/m

FA’01’01’00h => µ

ε

or µm/m

3. Request decimal digits (object 61’32h)

02h => 2 decimal digits => Divide with 10

2

02h => 2 decimal digits => Divide with 10

2

Configure of PDO settings:

1. Set PDO1 transmission type

FFh => transmit after run down of event timer

FFh => transmit after run down of event timer

2. Set PDO1 event timer (1sec)

03’E8h => 1000

Dez

=> Event timer = 1000ms

03’E8h => 1000

Dez

=> Event timer = 1000ms

3. Disable PDO1 mapping