3 Connections

3.1 Electrical connection

Connect the strain link according to the schematic below. Make sure the polarity is correct.
Use shielded cables.
The sensor housing and the cable shield must be grounded. Avoid differences in electrical potential between
parts of the system and the measuring chains.

3.1.1

Pin assignment

1

n.c.

2

+Vs

3

GND

4

CANH

5

CANL

housing

shield

3.1.2

Connection diagram


To comply with the PELV requirements according to EN 60204-1 Section 6.4.1, we recommend connecting
0V (GND) to the protective ground at one point in the system.